Polokwane

Polokwane juice sleeve

Steam Tunnel S after banding on nectar necks.

Polokwane nectar bottles after Steam Tunnel S sleeve finish

Polokwane juice sleeve

The Polokwane juice plant packs nectar in narrow-mouth bottles with 28 mm necks, and the brief was a clean tamper band on a short packing cell. The installation paired a Band Shrink 120 with a Steam Tunnel S, so the cut sleeve could be placed on the closure area and then shrunk tight with steam.

The job started after setters were spending too much time correcting neck bands during nectar runs. The plant needed a repeatable finish for transparent trial sleeves and branded production sleeves, with the tear line opening cleanly at the cap. The bottle also had to leave the steam area dry enough for downstream handling and cartons.

Survey and set-up sequence

The survey followed the bottle from capper discharge through the end of the packing cell. Side-guide pressure, bottle pitch, sleeve access, steam drainage and operator reach were checked on the Polokwane floor. The nectar bottle wall was also watched closely, because a warm bottle can show scuff marks if guides or neighbouring bottles touch it too firmly after shrink.

Set-up began with a dry conveyor run, then sleeve feeding on empty bottles, then steam trials on filled nectar bottles. Setters chose the sleeve width against the 28 mm closure and set the cut length so the perforation sat cleanly on the cap skirt. Steam pressure and dwell were increased one adjustment at a time, with sample bottles checked after each pass, until the band sat tight without sliding below the neck ring.

Fault found during commissioning

A fault appeared during commissioning as an occasional shiny mark on the bottle shoulder, with a few sleeves finishing lower than the approved sample. The pattern was random, so the first checks moved away from sleeve cut height. The trace started at the steam chamber entrance, where bottle spacing closed up under load and one guide touched the warm bottle face.

The fix was made on the line, not in the sleeve store. Side guides were opened by small indexed moves, infeed spacing was reset, and the sleeve magazine was aligned to present each cut band square to the cap path. Steam settings were then backed off and built up again. Marnus Esterhuizen ran marked bottles through the cell so the scuff point could be followed from banding to packing.

How Polokwane runs it now

The current start-up is practical for a trained setter. The operator warms the Steam Tunnel S, drains visible condensate, threads sleeve stock and runs a small batch before production release. The first checks are square band position, clean cap tear, no trapped water around the closure and no rubbing mark on the shoulder of the nectar bottle.

Changeovers stay close to the original Polokwane settings. For another nectar SKU on the same 28 mm neck, staff confirm artwork position and perforation first, then make small changes to steam pressure, dwell and bottle spacing if the bottle wall behaves differently. If a sleeve wrinkles under the cap bead or walks down the neck, the crew checks pitch, tray alignment and steam balance before changing material.

Care routine and follow-up

Maintenance is centred on steam cleanliness and moving parts. After production, staff wipe wet contact points, check the hood gasket for steam leaks, confirm belt tracking, clean sensors and remove sleeve dust from the feed path. The plant also keeps a restart note for stoppages, because a cold tunnel and a wet drain path can change the first bottles after a pause.

For longer care, the plant uses the Spares & Care Kit prompts and steam start notes such as steam start-up guidance. For another Polokwane-style nectar neck-band brief, send bottle photos, cap diameter, proposed band height, perforation position and available line space through our contact form.