Band Shrink 120 specs
Commission the Band Shrink 120 from the bottle outwards. At the 120 bpm running point, the machine needs regular infeed spacing, straight caps and sleeves that reach the steam hood square at production speed. Prove the number with the actual pack, then set the running speed where steam dwell, shrink finish and dry-off stay consistent through a normal operator shift.
Prepare services before placement
Bring steam to the hood with enough pressure at the take-off to shrink the chosen sleeve height on all sides of the neck. The 2.2 kW electrical supply feeds the tunnel heat, conveyor drive and controls, so route it to a local isolator with protected cabling. Plan condensate drainage at the outlet and follow the start-up sequence in Steam Start so operators warm the tunnel and drain wet lines in the same order.
Fit the sleeve to the neck and cap
Use the 20 to 60 mm sleeve height range as the format window for tamper coverage. Set the band position so shrink closes onto the cap skirt and upper neck, clear of shoulder beads, cap ridges and label edges. Put the tear line on the side where the customer can break the band without cutting across the brand panel. Size the sleeve from cap and neck diameters using band sleeve sizing notes, then set the sleeve feed tray to present each cut sleeve level to the bottle centre line.
Set the first running position
Start below the planned pack rate. Set body guides first, then bring the neck guides in only far enough to stop sway. Set feed height so the sleeve clears the cap top, settles straight and reaches the steam hood without rubbing. Open steam gradually and adjust dwell by line pace until the sleeve pulls down evenly from top to bottom, with no top lift, one-sided looseness or water trapped under the band.
Run samples and accept the format
Run a short batch using normal fill temperature, cap torque and bottle material. Take checks during start-up, after the tunnel has reached steady temperature, and again near the end of the trial batch. Check sleeve height, bottom edge level, perforation position, artwork orientation, dry shoulder and hand tear. If one side stays loose, clean the steam jets and check the drain before adding more steam. If the band creeps upward, recheck bottle pitch, guide pressure and feed timing. Record defects with photos for setter training.
Handover notes and sizing details
For handover, log the bottle reference, cap size, neck size, sleeve grade, sleeve lay-flat, cut height, tear-line direction, steam pressure, running pace, guide settings, condensate drain condition and drying setting. Add maintenance notes for jet cleaning, belt condition, tray wear and terminal checks, then schedule Band Shrink 120 service. For format sizing, send a message through our contact form with capped bottle samples, sleeve artwork, target pack rate, bottle pitch, shoulder shape and a short video of the sleeve entering the steam hood.
| Model | Band Shrink 120 |
|---|---|
| Rate band | Up to 120 bpm |
| Power / utilities | Steam + 2.2 kW |
| Neck / format | Sleeve heights 20 to 60 mm |
Back to Band Shrink 120.
What our Bottle Sealing customers say
Verified Google reviews
