Specify the Line Integration Rail from the bay layout, not from a loose dimension on a quote request. Start at the infeed transfer, mark the sealing cell position, then mark the reject side. The 1.5 to 6 m module length is the usable stretch for queuing, sensing, guiding, rejecting and clearing bottles without fouling a guard, post, drain cover or operator gate.
The rate on a rail job is the bottle presentation at the 24 V sensor. If pitch varies, the reject timing chases the wrong pack, so the first floor task is to run bottles at the planned pace and watch the gap. The sensor kit is set for one clean trigger per bottle, with the cable route protected from wash-down, trolleys and foot traffic.
Prepare the site and utilities
Set a straight centreline between the upstream conveyor and the machine built around the rail, then confirm conveyor height, floor fall and fixing positions. Bring 24 V sensor power, reject signal wiring and any stop-start interface to the setter side of the cell. Use the retrofit bay sketch method to mark access for spanners, guard opening, sample removal and rejected packs before the frame is drilled down.
Fit the guides and reject station
Level the frame, square it to the conveyor and set the adjustable guides around the bottle body before locking brackets. The 28, 33, 38 and 45 mm format numbers describe the closure family that must travel on centre through the cell. Confirm the bottle does not lean on the guide through starts, stops and full cases. Fit the reject pocket where a removed bottle can land clear of the main flow and be seen by the operator.
Set, sample and accept the run
First settings are made with filled production bottles, production caps and the normal case change rhythm. Record guide opening, sensor height, sensor distance to reject, reject dwell and restart gap. Where the rail feeds a Seal Induction Pro or a vision cell, match the rail trigger to that machine’s infeed timing. Floor faults show as late rejects, two packs moving together, scuffed labels, neck rub, rocking tall bottles or a missed trigger after a short stop.
Run a sample that includes steady running, a stop, a restart, a deliberate reject and the next case of bottles. Acceptance is based on plain observations: sensor count matches bottle count, accepted bottles stay centred, rejected bottles leave the flow, clamps stay tight and the line setter can repeat the start-up without calling maintenance. For inspection cells, the reject action must match the inspection result on the same bottle, not the one behind it.
Write down the handover and send sizing details
Handover notes should list module length, conveyor height, guide opening, neck finish, bottle pitch, reject side, sensor position, reject delay, SKU names and bracket positions changed during commissioning. Add photos from the operator side and reject side. The handoff template gives maintenance leads and setters one record for the next changeover, shift cover or service visit.
For sizing, send a bay sketch, conveyor width, transfer photos, bottle height and diameter, filled weight, neck finish, cap type, label position, planned pace, reject side and the sealing or inspection machine fitted around the rail. Send a message through our contact form, or bring sample packs to the counter in Meadowdale Industrial, Germiston, so the rail length, guide format, sensor bracket positions and reject layout can be set against the actual plant floor.
| Model | Line Integration Rail |
|---|---|
| Rate band | Modular 1.5 to 6 m |
| Power / utilities | 24 V sensors |
| Neck / format | Adjustable guides |