For R&D benches, pilot batches and short contract-packing runs, the Seal Induction Compact gives induction sealing capacity without taking the floor space of a conveyor cell. Its rated pace, up to 25 bpm, is an operator-paced bench figure: cap the bottle, place it squarely under the head, run the dwell and remove it.

The 20 to 38 mm neck range is the first sizing gate. Measure the bottle neck finish and match the closure and liner before heat is tried. Within that range, the 1.2 kW induction head heats the aluminium foil liner through the cap. Cap torque supplies pressure on the bottle land; the alternating field supplies heat into the foil layer.

Prepare the bench and utilities

Put the Compact on a flat, stable bench with capped infeed samples on one side and cooled sealed samples on the other. Keep the power lead off the walking path and have the plant electrician check the supply against the 1.2 kW load. The operator needs repeatable hand position and good light over the cap top.

Prepare the consumables as one set: bottle, cap, wad, product sample and torque target. Use the foil neck chart to confirm the liner style against the South African neck finish, then select matching Foil & Die Kit parts where cut wads are being made for 28, 33 or 38 mm closures.

Fit the head to the bottle

Set the capped bottle under the coil with the cap top level and centred. The head face must sit parallel to the closure, with a measured air gap between the face and the cap top. In sound physics, that air space controls energy transfer at the foil: extra height reduces heating, while too little clearance can concentrate heat at the liner.

Write the first gap on the job sheet before changing dwell. Use the coil gap guide as the starting reference, then tune on actual bottles. If the bottle rocks, the cap is domed, or the closure is cross-threaded, correct the mechanical fault first. Heat settings work after seating and bottle land condition are sound.

Set, run and read the first samples

Start with cap torque. A loose cap gives patchy contact on the land; a cap wound past the torque target can pull the closure out of shape, wrinkle the wad or change pressure on the sealing face. Where torque is part of the packing brief, link the bench work to the same closure target used on the Cap Torque Station so trial seals and packed stock are judged against one closure condition.

Run a small agreed sample set at the starting gap and dwell. Let the samples cool before opening, then check the foil face and the bottle land. Typical Compact setting faults show as a dry edge, a bonded centre with lifted shoulder, scorched liner, softened neck land, cap dust on the head face, or a wad that turns with the cap.

Accept the run and record handover data

Acceptance is a bench decision made from the agreed sample count, opened seals and leak checks. On the Compact record, log the product code, container resin, measured neck finish, closure type, liner grade, torque target, coil gap, dwell, operator pace and the final pass sample kept for reference. Use the handoff template so the next setter can repeat the same bench job.

For Compact sizing, send bottle samples, closures, liners, neck finish details, product description, expected batch size, target bench pace, photos of the cap top and land, and any current seal failures through our contact form. The most useful trial pack includes both good and failed examples, because the head gap, dwell and torque can then be set against the actual closure stack.