Seal Inspect Vision service
The Seal Inspect Vision works on capped bottle lines where missing foils, partial seal faces and bad cap presentation must be removed before cartons are built. Service is floor-level: clean the view, prove the trigger, test the air blast, then run known good and faulty bottles at normal pitch. Sauce, edible oil, syrup and export lines need attention to splash marks and cabinet dust.
For access work, bring the conveyor to a standstill, isolate the electrical supply, lock it out, and bleed the pneumatic supply feeding the reject. Confirm zero pressure at the regulator, check that the blast cannot fire, and let the inspection camera and light module shut down. After work, close guards, restore air, restore power, load the inspection job and record the first reject test.
Shift, weekly, monthly and quarterly care
Each shift, wipe the camera window and LED window with a lint-free cloth, check bottle guide position, and run one passed sample plus one failed sample through the gate. Watch that rejected bottles land in the pocket and do not bounce back into traffic. After a power cut, use the power-cut restart notes, then recheck timing before speed is raised.
Weekly care covers air and mounting points. Drain the filter bowl, inspect the regulator reading during a reject, clean the nozzle tip, check the trigger sensor face, and tighten the camera, light and nozzle brackets. Monthly work adds inspection recipe backup, cabinet dust removal, plug cleaning and a reject timing check against the vision reject map. Quarterly service covers air tubing, sensor leads and filter elements.
Wear parts and what wear looks like
The wear items on Seal Inspect Vision are small, but they change pass and fail calls quickly. A scratched lens cover gives grey, low-contrast images. A hazy or chipped LED window creates shadows across the cap. A tired vision light bar may flicker or show dark sections. A trigger sensor with a scuffed face can miss bottles at tight pitch. Chafed air tubing, a sluggish solenoid, an oval nozzle tip or water in the bowl show as weak or late rejects.
Fault symptoms, likely cause and floor fix
When good bottles are being rejected, start with dirt and product mist on the viewing parts. Clean the camera and LED windows, then run the last accepted bottle again. If rejects continue, check whether the bottle height, cap colour, foil colour or guide setting changed during a SKU swap. Reload the correct inspection job and run good and faulty samples as a pair.
When failed bottles pass through, look at the reject side before blaming the camera. A falling regulator reading, product in the nozzle tip, a sticky solenoid or wrong blast delay can leave a failed cap travelling with the good lane. Clean the nozzle, drain the filter, prove the solenoid by manual test, then adjust the reject mark until the bottle lands cleanly in the reject pocket.
Double rejects, tipped bottles and scuffed labels usually point to bottle control. Set the side guides so the bottle arrives square to the camera, not leaning into the rail. Check that the pocket is not full, the reject blast is not aimed too low, and the next bottle gap has not collapsed after a capper stop. After any rail move, rerun pass and fail samples.
Booking a technician visit
For a Seal Inspect Vision call-out pack, send us the machine serial number, neck sizes in use, cap colours, foil colours, current inspection job name, speed setting and air pressure reading during reject. Include three clear photos: camera view, reject station and cabinet interior, plus a short phone video of the fault at normal speed. For planned service, inspection camera covers, light windows, nozzle parts and filter items can be prepared through Bheki Msimang, with collection from the Meadowdale Industrial, Germiston counter.