Service

Spares & Care Kit service

Care cadence, spares, and what to send us before a visit.

Spares & Care Kit service

The Spares & Care Kit service programme gives plant teams a fixed rhythm for induction sealer care, with the job card, small wear parts and fault notes kept together. It suits production floors where setters inherit the machine between shifts and maintenance needs a clean record of belt changes, sensor knocks, head face wear, restart settings and seal checks on Seal Induction Pro and Seal Induction Compact units.

Before any cover is removed or a guard is opened, stop the infeed, clear bottles from the sealing area, switch the sealer off at the machine isolator and lock it out. Prove the control panel is dead, wait for warm surfaces and cooling fans to settle, then remove trapped caps, liners and product residue. The person doing the work signs the kit card before the machine returns to production.

Service cadence on the line

Each shift, wipe the sensor face, check that bottles pass square under the head, confirm the belt runs central on its rollers and record the product, cap, liner and last working setting. Run start-up samples after lunch breaks, power interruptions and capper changes. If a setter adjusts cap torque, guide rails or bottle pitch, the change goes on the same Spares & Care Kit card.

Weekly, remove cap dust and product film from the sealer body, inspect the belt edge, look for loose sensor brackets and check plug strain relief where operators reach during changeover. Monthly, inspect roller bearings, belt tension, guard switches, cooling vents and stored recipes against the spares schedule. Every three months, fit flagged wear parts, update the job card and book work that needs a technician.

Wear parts and what wear looks like

The belt is the first item most setters notice. A shiny belt top, feathered edge, cracked join or wandering track points to stretched material, over-tightening or product build-up on rollers. Fit the kit belt when tracking no longer holds after cleaning and tensioning. Record which side was frayed, because repeat wear on one edge often points to a guide rail or transfer height problem.

Sensors wear in quieter ways. A scratched lens, oil film, bent bracket or cable pulled tight at the gland can give random missed bottles. Clean the face, tighten the bracket, check the trigger position with bottles at production pitch and replace the sensor if the fault moves with the sensor lead. Head face pads and covers are changed when they show grooves, heat marks, loose fasteners or liner scuff patterns.

Fault symptoms, causes and fixes

Patchy seals across one SKU often start with cap torque drift, a dirty bottle land, worn head face material or bottles sitting off-centre under the sealer. The fix is to clean the sealing path, reset the capper, square the guides and run fresh samples with the last good setting. Use the kit card to record the cap type and liner batch, not just the machine setting.

Random unsealed bottles point to sensor timing, a loose bracket or bottles slipping on a tired belt. Clean and clamp the sensor, check bottle pitch through the sealer and replace the belt if it slips under normal load. Scuffed aluminium liners point to cap wobble, raised liner edges or contact marks on the head face. Replace damaged caps, correct torque and fit the flagged face part.

After stoppages and before a visit

After a power cut, restart from the recorded product setting and follow the power-cut restart steps before packing product. Send us the sealer model, completed kit card, last good setting, photos of worn parts, fault symptoms, bottle neck size, cap type, liner type and any parts already fitted. For technician planning, Bheki Msimang uses those notes to pack the correct items for work from the counter at Meadowdale Industrial, Germiston.

Talk to the sealing counter

Contact form · Meadowdale Industrial, Germiston